{"id":25284,"date":"2026-04-28T15:19:46","date_gmt":"2026-04-28T12:19:46","guid":{"rendered":"https:\/\/kolmeks.com\/pumps\/kaksoispumput\/"},"modified":"2026-06-30T13:06:50","modified_gmt":"2026-06-30T10:06:50","slug":"kaksoispumput","status":"publish","type":"page","link":"https:\/\/kolmeks.com\/en\/pumps\/kaksoispumput\/","title":{"rendered":"Twin pumps"},"content":{"rendered":"\n<div class=\"wp-block-group alignfull has-light-grey-background-color has-background has-global-padding is-layout-constrained wp-container-core-group-is-layout-49c16d9b wp-block-group-is-layout-constrained\" style=\"border-top-left-radius:8px;border-top-right-radius:8px;border-bottom-left-radius:8px;border-bottom-right-radius:8px;padding-top:var(--wp--preset--spacing--70);padding-right:var(--wp--preset--spacing--40);padding-bottom:var(--wp--preset--spacing--70);padding-left:var(--wp--preset--spacing--40)\">\n<div class=\"wp-block-columns are-vertically-aligned-center is-layout-flex wp-container-core-columns-is-layout-794e3cfa wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:100%\">\n<h1 class=\"wp-block-heading\">Twin pumps<\/h1>\n\n\n\n<p class=\"has-text-m-font-size wp-block-paragraph\"><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:100%\">\n<div style=\"aspect-ratio:1;min-height:unset;\" class=\"wp-block-cover has-aspect-ratio\"><img decoding=\"async\" width=\"1024\" height=\"1024\" class=\"wp-block-cover__image-background wp-image-22403 size-large\" alt=\"\" src=\"https:\/\/kolmeks.com\/wp-content\/uploads\/2026\/05\/05_018_T-50B_2_11kW_right-1024x1024.png\" data-object-fit=\"cover\" srcset=\"https:\/\/kolmeks.com\/wp-content\/uploads\/2026\/05\/05_018_T-50B_2_11kW_right-1024x1024.png 1024w, https:\/\/kolmeks.com\/wp-content\/uploads\/2026\/05\/05_018_T-50B_2_11kW_right-300x300.png 300w, https:\/\/kolmeks.com\/wp-content\/uploads\/2026\/05\/05_018_T-50B_2_11kW_right-150x150.png 150w, https:\/\/kolmeks.com\/wp-content\/uploads\/2026\/05\/05_018_T-50B_2_11kW_right-768x768.png 768w, https:\/\/kolmeks.com\/wp-content\/uploads\/2026\/05\/05_018_T-50B_2_11kW_right-1536x1536.png 1536w, https:\/\/kolmeks.com\/wp-content\/uploads\/2026\/05\/05_018_T-50B_2_11kW_right-2048x2048.png 2048w, https:\/\/kolmeks.com\/wp-content\/uploads\/2026\/05\/05_018_T-50B_2_11kW_right-600x600.png 600w, https:\/\/kolmeks.com\/wp-content\/uploads\/2026\/05\/05_018_T-50B_2_11kW_right-100x100.png 100w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><span aria-hidden=\"true\" class=\"wp-block-cover__background has-background-dim-0 has-background-dim\"><\/span><div class=\"wp-block-cover__inner-container is-layout-flow wp-block-cover-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><\/p>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n\n  <div style=\"border: 2px dashed #a0aec0; border-radius: 4px; padding: 1.5rem; text-align: center; color: #718096; font-size: 0.9rem;\">\n    Category Product List \u2014 rendered on the category archive page  <\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns alignwide is-layout-flex wp-container-core-columns-is-layout-bf2f7638 wp-block-columns-is-layout-flex\" style=\"margin-top:var(--wp--preset--spacing--70);margin-bottom:var(--wp--preset--spacing--70)\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:100%\">\n<h2 class=\"wp-block-heading\">Pump Structure and Operating Principle<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">T and AT series twin pumps are vertical in-line centrifugal pumps with a two-part pressure chamber cast as a single piece.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Alternation of the pump units can be easily automated, as valves do not need to be opened or closed during switching. The pump is equipped with an automatic check valve to prevent internal circulation if only one pump is operating or if the other is removed for maintenance. When one pump unit is replaced with a blind cover, the other unit can be operated independently. Note that the check valve does not function as a system-required non-return valve. Twin pumps are available with constant speed operation or with an integrated frequency converter. Pumps with a frequency converter can be equipped with pressure or temperature transmitters and controlled by external automation systems.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<div style=\"height:1em\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Applications, Size Range and Technical Data<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">T and AT series pumps can be used for circulation, pressure boosting, and transfer of clean liquids in closed and open systems in applications requiring high dependability, reliability, and a wide range of pumping capacity on demand.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The range covers flanged pump sizes DN32\u2013DN125 (ISO 7005) and power ratings from 0.05 kW to 22 kW (per unit). The bearings of the electric motors are permanently lubricated and maintenance-free. The modular structure of the pump allows for easy maintenance and replacement of components.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A wide range of accessories and optional features is available for the pumps.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><br>Operating principles of a twin pump:<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">a) Standby pump and alternating operation:<br>When one pump unit is operating, the other acts as an automatic standby pump, which is started by the automation system if the running pump stops, for example due to a thermal relay trip. Alternating operation is recommended to ensure even operating hours for both units, keeping them in similar condition. A suitable alternation interval can be achieved, for example, with a weekly timer.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">b) The twin pump can also be operated so that high flow rates are pumped with both units simultaneously, while only one unit operates under low demand. In this mode, the operating points must be carefully determined using the pump QH curves and the system characteristic curves. Particularly in circulation systems, parallel operation of even identical pumps often does not result in increase in pumping capacity. This operating mode may be suitable for applications with static head, such as transferring liquid from a lower level tank to a higher level. Alternating operation is also recommended in this operation mode to maintain good condition of the units.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Pumped fluid temperature:<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Constant speed operation and NC frequency converter: <br>-10 \u2026 120 \u00b0C (depending on sealing solution).<\/li>\n\n\n\n<li>MD frequency converter: -10 \u2026 90 \u00b0C<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><br><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:100%\">\n<div class=\"wp-block-group has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\">\n<div class=\"wp-block-group has-border-color has-light-grey-background-color has-background has-global-padding is-layout-constrained wp-container-core-group-is-layout-0910e091 wp-block-group-is-layout-constrained\" style=\"border-color:#C2C2C2;border-width:1px;border-top-left-radius:16px;border-top-right-radius:16px;border-bottom-left-radius:16px;border-bottom-right-radius:16px;padding-top:var(--wp--preset--spacing--40);padding-right:var(--wp--preset--spacing--40);padding-bottom:var(--wp--preset--spacing--40);padding-left:var(--wp--preset--spacing--40)\">\n<h3 class=\"wp-block-heading\">Advantages of Kolmeks Twin Pumps:<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Easy alternation between pump units, as no valves need to be opened or closed.<\/li>\n\n\n\n<li>Seasonal operation: higher flow demand during the heating season can be achieved with two units, while lower demand during holiday periods can be run with a single unit.<\/li>\n\n\n\n<li>User-friendly and space-saving for applications requiring high adaptability. With frequency converters, the pump automatically adjusts to varying demands.<\/li>\n\n\n\n<li>Reliable operation even in unforeseen situations: during maintenance, the unit being under service can be replaced with a blind cover, while the other unit remains in operation.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Operating range<\/p>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><img decoding=\"async\" width=\"1024\" height=\"585\" src=\"https:\/\/kolmeks.com\/wp-content\/uploads\/2026\/05\/curve_plot_2026-02-13_14-51-27-1024x585.png\" alt=\"\" class=\"wp-image-22408\" style=\"aspect-ratio:1.7505295827380658;width:555px;height:auto\" srcset=\"https:\/\/kolmeks.com\/wp-content\/uploads\/2026\/05\/curve_plot_2026-02-13_14-51-27-1024x585.png 1024w, https:\/\/kolmeks.com\/wp-content\/uploads\/2026\/05\/curve_plot_2026-02-13_14-51-27-300x171.png 300w, https:\/\/kolmeks.com\/wp-content\/uploads\/2026\/05\/curve_plot_2026-02-13_14-51-27-768x439.png 768w, https:\/\/kolmeks.com\/wp-content\/uploads\/2026\/05\/curve_plot_2026-02-13_14-51-27-600x343.png 600w, https:\/\/kolmeks.com\/wp-content\/uploads\/2026\/05\/curve_plot_2026-02-13_14-51-27.png 1400w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-794e3cfa wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-heading\"><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n<\/div>\n<\/div>\n\n\n\n<h3 class=\"wp-block-heading\">Advantages of Kolmeks VFD pumps:&nbsp;<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>The pump adjusts to the system, ensuring silent operation.<\/li>\n\n\n\n<li>Pumping capacity is based on actual demand, resulting in lower lifecycle costs.<\/li>\n\n\n\n<li>Payback period compared to a fixed speed pump is 0.5\u20132.5 years depending on the model (see example chart).<\/li>\n\n\n\n<li>Alarms can be connected to external systems.<\/li>\n\n\n\n<li>The operating point can be precisely adjusted (domestic hot water).<\/li>\n\n\n\n<li>Operates according to system conditions (radiator and ventilation circulation).<\/li>\n\n\n\n<li>Energy saving.<\/li>\n\n\n\n<li>Robust and reliable.<\/li>\n\n\n\n<li>Extended pipeline network lifetime.<\/li>\n\n\n\n<li>MD and NC inverter pumps can also be safely controlled remotely via Bluetooth connection.<\/li>\n<\/ul>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-794e3cfa wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"wp-block-paragraph\">Cost Comparison<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"683\" src=\"https:\/\/kolmeks.com\/wp-content\/uploads\/2026\/06\/Cost-Comparison-1024x683.jpg\" alt=\"\" class=\"wp-image-25991\" srcset=\"https:\/\/kolmeks.com\/wp-content\/uploads\/2026\/06\/Cost-Comparison-1024x683.jpg 1024w, https:\/\/kolmeks.com\/wp-content\/uploads\/2026\/06\/Cost-Comparison-300x200.jpg 300w, https:\/\/kolmeks.com\/wp-content\/uploads\/2026\/06\/Cost-Comparison-768x512.jpg 768w, https:\/\/kolmeks.com\/wp-content\/uploads\/2026\/06\/Cost-Comparison-600x400.jpg 600w, https:\/\/kolmeks.com\/wp-content\/uploads\/2026\/06\/Cost-Comparison.jpg 1397w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-media-text alignwide is-stacked-on-mobile is-image-fill-element has-aqua-blue-background-color has-background\" style=\"border-top-left-radius:16px;border-top-right-radius:16px;border-bottom-left-radius:16px;border-bottom-right-radius:16px;margin-top:var(--wp--preset--spacing--70);margin-bottom:var(--wp--preset--spacing--70);grid-template-columns:30% auto\"><figure class=\"wp-block-media-text__media\"><img decoding=\"async\" width=\"682\" height=\"1024\" src=\"https:\/\/kolmeks.com\/wp-content\/uploads\/2026\/03\/huolto-1-682x1024.jpg\" alt=\"\" class=\"wp-image-403 size-full\" style=\"object-position:50% 50%\" srcset=\"https:\/\/kolmeks.com\/wp-content\/uploads\/2026\/03\/huolto-1-682x1024.jpg 682w, https:\/\/kolmeks.com\/wp-content\/uploads\/2026\/03\/huolto-1-200x300.jpg 200w, https:\/\/kolmeks.com\/wp-content\/uploads\/2026\/03\/huolto-1-768x1152.jpg 768w, https:\/\/kolmeks.com\/wp-content\/uploads\/2026\/03\/huolto-1-1024x1536.jpg 1024w, https:\/\/kolmeks.com\/wp-content\/uploads\/2026\/03\/huolto-1-600x900.jpg 600w, https:\/\/kolmeks.com\/wp-content\/uploads\/2026\/03\/huolto-1.jpg 1333w\" sizes=\"(max-width: 682px) 100vw, 682px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<div class=\"wp-block-group has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\" style=\"padding-top:var(--wp--preset--spacing--50);padding-bottom:var(--wp--preset--spacing--50)\">\n<h2 class=\"wp-block-heading has-white-color has-text-color has-link-color wp-elements-ddf694c82152c8cd6f710f0b0a0ad65f\">24\/7 maintenance and spare parts services<\/h2>\n\n\n\n<p class=\"has-white-color has-text-color has-link-color wp-elements-c79e9d770d1b1ddd9489c932bbffd168 wp-block-paragraph\">Kolmeks provides spare parts and maintenance services for pumps and air separators. We service pumps of various sizes reliably and professionally, ensuring their efficient and trouble-free operation.<\/p>\n\n\n\n<p class=\"has-white-color has-text-color has-link-color wp-elements-90869d280b2b5a4608c5d2ff8756c1c3 wp-block-paragraph\">We offer responsive maintenance support and spare parts services to keep our customers\u2019 systems up and running in all situations.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"\/?product_cat=services\">Maintenance and parts<\/a><\/div>\n<\/div>\n<\/div>\n<\/div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Twin pumps Pump Structure and Operating Principle T and AT series twin pumps are vertical in-line centrifugal pumps with a two-part pressure chamber cast as a single piece. Alternation of the pump units can be easily automated, as valves do not need to be opened or closed during switching. The pump is equipped with an [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":8425,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-25284","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/kolmeks.com\/en\/wp-json\/wp\/v2\/pages\/25284","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/kolmeks.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/kolmeks.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/kolmeks.com\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/kolmeks.com\/en\/wp-json\/wp\/v2\/comments?post=25284"}],"version-history":[{"count":0,"href":"https:\/\/kolmeks.com\/en\/wp-json\/wp\/v2\/pages\/25284\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/kolmeks.com\/en\/wp-json\/wp\/v2\/pages\/8425"}],"wp:attachment":[{"href":"https:\/\/kolmeks.com\/en\/wp-json\/wp\/v2\/media?parent=25284"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}